 | PLC software | It is compatible with FX3U PLC GX Works2 software. | 
| Ethernet port | Number of socket channels: 4 Supported protocols: MODBUS-TCP protocol Maximum support for 4 slaves Bandwidth: 10/100Mbps Support for downloading programmes over LAN Default IP: 192.168.1.80 | 
| High-speed input | 2-channel X00 X01 (200khz) Trigger voltage 9-28VDC Trigger current >3mA | 
| 232 communication port | Channel number: 1 Baud rate range: 1200~115200Bps Data format: 8N1/8O1/8E1/8N2/7N1/7O1/7E1/7N2 Protocol: MODBUS-RTU Isolated voltage: 24VDC | 
| 485 communication port | Channel number: 2 Baud rate range: 1200~115200Bps Data format: 8N1/8O1/8E1/8N2/7N1/7O1/7E1/7N2 Protocol: MODBUS-RTU Isolated voltage: 5kVrms | 
| Analog input port | 
Channel number: 2 Current input range: 0~25mA (3~28VDC) Voltage input range: 0~10VDC Acquisition interval: 0.1~1Khz ultimate voltage: 28VDC | 
| Analog output port | 
Channel number: 2 Current input range: 0~20mA (24VDC) Voltage input range: 0~10VDC (<=20mA) 
Response time: Greater than 10mS | 